Parameter
Range
0 - 100 ppm
Precision
<2% or 3ppb (use the greater as standard)
Accuracy
±3% (≥500ppb)
Calibration period
About 2 hours
Analysis time
About 4.5 mins at the fastest
Inorganic carbon treatment
Do high levels of inorganic carbon samples
require expensive extra modules to remove
the inorganic carbon?
No
Is dynamic endpoint detection used to ensure
complete removal of the inorganic carbon?
Yes
Self-diagnostic function ensures data integrity
Will the instrument report TOC if the following conditions occurs?
UV lamp intensity is too low
Insufficient carrier gas / empty tank
Insufficient reagent / empty bottle
Insufficient sample volume / empty vial
Reagent
Reagent supply
Purchased or self prepared
Is there an option to prepare your own
reagent
Total number of reagents (acid, oxidant,
dilution water)
One
Measurement method and guarantee
Oxidation
UV lamp + persulfate
Confirmation of UV lamp
Broadband silicate photodiode sensor
Detector
Digital NDIR
Stability of detector
Continuously verify according to reference value
Detector moisture pre removed
Peltier cooler with continuous current monitoring
Distribution module
Using syringe pump, accurate to ±1% of the volume
Flow Sensor
Dynamic fluid detector (to ensure the accuracy of sample and reagent volume)
Carrier gas selection
High purity air, oxygen or nitrogen
Confirmation of carrier gas pressure
Double orifice pressure sensor
Closing of carrier gas valve
After the measurement, the valve will close to avoid wasting gas
Auto range furnction
Analysis mode
NPOC (non-purge organic carbon)
Data storage and retrieval
Statutory certification
All measurement results for 21 CFR, Part 11 are recorded in an encrypted database
Paperless report
Output report via Ethernet network shared directory managed by Windows security policy
IO (input and output)
3 USB ports, 1 Ethernet port
Data export format
PDF, CSV
User Interface
display
10.4" high resolution color touch screen
External PC
No external hardware, Windows 10 IoT Enterprise operating system embedded
External keyboard / mouse
Optional, not required
Easy operation
Intuitive user interface, guide the operator through measurement settings
Technical regulations
Calibration
Automated processing: 18-point calibration with KHP (3 repetitions each at 5 different concentration, 3 background)
Calibration solution
5 ppm C, KHP (single 125ml bottle), diluted with reagents to concentrations of 1, 2, 3, 4, 5 ppm)
Verification test / system suitability
Automation routine:
* USP SST bulk water
Blank, 500 ppb in C: sucrose, P-
benzoquinone
* USP SST sterile water
Blank, 8 ppm in C: sucrose, P-
* JP-16 <2.59> validation Blank, 500 ppb
in C SDBS
Compliance
USP <643> (including sterile water SST), JP-16 <2.59>, EP <2.2.4>,
IP, CP, KP, US EPA 5310c
21 CFR, Part 11
ICH guidelines for instrument validation includes: accuracy,
precision, detection limit, quantitative limit, linearity, range,
specificity, durability
Auto sampler
Capacity
64 sampling bottles (40ml glass vial for TOC)
Style
XYZ spacer perforation
Sample tray material
Aluminum anodizing
General technical data
Instrument size
(W)320 x (D)507 x (H)410 mm
Power
100 - 240 VAC, 50/60 Hz, 2A
Weight
14kg (31 lbs)
Auto sampler size
(W)366 x (D)537 x (H)457 mm
100 - 240 VAC, 47 - 63 Hz
21 kg (45 lb)
Temperature and Humidity
5-35℃; relative humidity up to 90%, non-condensing
Unit
㎍/L (ppb)